* Depending on setting
Disch. valve leak
(Alarm)
Leaky/dirty outlet valve. Dosing
medium flows back from the outlet
line into the dosing head and
moves the motor.
Inlet pressure too high. Dosing
medium flows from the inlet line
into the dosing head and moves
the motor.
Replace valve if necessary. See section
8.4 Perform service.
Install screen in inlet line.
Reduce inlet pressure. Observe section
4.1 Technical data.
Cavitation
(Alarm)
Blocked / constricted / squeezed
inlet line
Blocked/constricted inlet valve
Suction lift too high
Viscosity too high
Cavitation moves the motor
Enable "SlowMode". See section
7.6
SlowMode
.
Reduce suction lift.
Increase inlet line diameter.
Check inlet line and open isolating valve if
necessary.
Overheating
(Alarm)
Motor is overheated Reduce ambient temperature.
Stop pump until motor cools down.
Service now
(Warning)
Time interval for service expired Perform service. See section 8.4 Perform
service.
Display in the
"Alarm" menu
Possible cause Possible remedy

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos SMART Digital XL DDA 200-4 and is the answer not in the manual?

Grundfos SMART Digital XL DDA 200-4 Specifications

General IconGeneral
BrandGrundfos
ModelSMART Digital XL DDA 200-4
CategoryWater Pump
LanguageEnglish

Related product manuals