EasyManuals Logo

Gryphon Commander User Manual

Gryphon Commander
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
33
Input Impedance, balanced: 18K
Input Impedance, single-ended: 12K
Output impedance: 7
Bandwidth (-3dB): 0.1Hz to 1.5MHz
Gain: +18dB
THD + N: 0.003% @ 1kHz and BW 10Hz 30KHz, balanced output
Max output level, balanced: 19Vrms
Max output level, single-ended: 9,5Vrms
Max input level, balanced: 20Vrms
Max input level, single-ended: 10Vrms
Power consumption: ≤ 0.5W (standby), 90W (idle)
AC voltage range 110-120V or 220-240V - factory changeable only.
MENU-controlled functions:
Volume Max Level
Voume Start Level
Balance, Left/Right. (6dB in 1dB steps)
Output level: “Normal” or “-6dB”
Display Intensity: (100%-75%-50%-25%, Auto Dim and Auto OFF)
Green Bias setup
Infra-Red source (Front or Rear Panel)
PSU option out enable
Input Level Match
Input Naming
Dedicate Input 4 (XLR) or input 5 (RCA) to Volume-Bypass AV-input
Restore Settings
Dimensions Preamplifier unit, WxHxD: 48 x 23,6 x 45,5 cm, net unit weight: 30,5kg
Dimensions PSU unit, WxHxD: 48 x 23,6 x 44 cm, net unit weight: 38,2kg
Please also see following pages
Shipping dimensions: Two crates; each 59 x 57 x 38 cm, respectively 45kg and 53kg
Note: Specifications can be changed without notice.