33
• Input Impedance, balanced: 18KΩ
• Input Impedance, single-ended: 12KΩ
• Output impedance: 7Ω
• Bandwidth (-3dB): 0.1Hz to 1.5MHz
• Gain: +18dB
• THD + N: 0.003% @ 1kHz and BW 10Hz – 30KHz, balanced output
• Max output level, balanced: 19Vrms
• Max output level, single-ended: 9,5Vrms
• Max input level, balanced: 20Vrms
• Max input level, single-ended: 10Vrms
• Power consumption: ≤ 0.5W (standby), 90W (idle)
• AC voltage range 110-120V or 220-240V - factory changeable only.
• MENU-controlled functions:
Volume Max Level
Voume Start Level
Balance, Left/Right. (6dB in 1dB steps)
Output level: “Normal” or “-6dB”
Display Intensity: (100%-75%-50%-25%, Auto Dim and Auto OFF)
Green Bias setup
Infra-Red source (Front or Rear Panel)
PSU option out enable
Input Level Match
Input Naming
Dedicate Input 4 (XLR) or input 5 (RCA) to Volume-Bypass AV-input
Restore Settings
• Dimensions Preamplifier unit, WxHxD: 48 x 23,6 x 45,5 cm, net unit weight: 30,5kg
• Dimensions PSU unit, WxHxD: 48 x 23,6 x 44 cm, net unit weight: 38,2kg
Please also see following pages
• Shipping dimensions: Two crates; each 59 x 57 x 38 cm, respectively 45kg and 53kg
Note: Specifications can be changed without notice.