PX/QX/RX Version 4.20 User Manual – Issue B
- 37
-
Alarm & Event Log messages
Log Text Additional Data Display Text
Event Description
Isolate User nn, RMm Usnn, RMm Radio module isolated by user
Jamming Radio module number
RM nn Receiver jammed
Key Fail User nn Usnn Encryption key fail
Knock Circuit nnn Cctnnn Circuit first knock
Late Working Usnn, Area m Usnn, Am Late working has been selected
for the area
Line Fault
Module name
Module name
Module has reported a line fault
Lockout Keypad n KPn Incorrect code attempt limit
reached on the keypad
Logged Off User nn, Keypad m
Usnn, KPm User logged off keypad
Logged On User nn, Keypad m
Usnn, KPm User logged on keypad
Managed Rst Keypad m KPm Managed reset code entered
Marginal Circuit nnn Cctnnn A Circuit is marginal
Mult. Alarm Circuit nnn Cctnnn Circuit has alarmed up to the
multiple alarm limit
Normal User nn, Concm Usnn, m Isolate removed from a
concentrator
Normal User nn, Circuit mmm
Usnn Cctmmm
Bypass or isolate removed from
a circuit
Not Unset Area n An
A set group was not unset by the
schedule close time
Panel Tamper NONE NONE Panel case or off the
wall tamper
PC Access GSRx Operator YY
GSRx Operator
YY
GSR operator number YY has
logged on from GSR number x.
PC Disconnect GSRx Operator YY
GSRx Operator
YY
GSR operator number YY has
logged on from GSR number x.
Personal Attack Circuit nnn Cctnnn A PA type circuit alarm
Poll Fail Transmitter number TX nn, RM mm
Transmitter polling failure
Poll Fault Radio module number
RM nn Receiver polling fault
Power Fail NONE (see note) NONE Supply voltage has
fallen to the power fail threshold
PSTN Route Fail NONE NONE A call using the Dual comm
PSTN route has failed.
PSTN Route OK NONE NONE A call using the Dual comm
PSTN route was successful.
Remote Service GSRx GSRx Remote Service Complete
Reprogrammed Refer to table Refer to table Item menu description plus
optional number (see note)
Reset Circuit nnn Cctnnn An area has been reset
Reset User nn, Area m Usnn, Usnn An area has been reset
Restored Code(s) User nn, Keypad m Usnn, KPm All codes have been restored to
default
Rmt.Auth Fail NONE NONE Repeated attempt to log on by a
remote host
Session End User nn Usnn Encryption session end
Set User nn, Area m Usnn Am Area has been set by a user
Set User nn, Group m Usnn m Group has been set by a user
Set Req. Circuit nnn Cctnnn Key type circuit alarms
Set Req. User nn, Keypad m Usnn, KPm A user requested set on a
keypad (dual set programmed)
Shunt Limit Area n An The shunt limit for the system
has been reached.
Shunt Off User nn, Circuit mmm
Usnn Cctmmm
Shunted removed from circuit
Shunt On User nn, Circuit mmm
Usnn Cctmmm
Shunt applied to circuit
Sndr Tamper NONE NONE Panel sounder tamper