6. MAINTAINING THE CHARGER
Periodically clean both battery terminals with baking soda and tighten all connections.
No other maintenance on the charger is required.
7. SPECIFICATIONS
Output:
Charging: 12 Volts DC(min.) at 6 Amps
Maintaining: 13.30 Volts DC at 0.1 Amps
Input:
Rated AC Voltage 100 – 130 VAC, 50/60 Hz
Current Draw 1.6 Amps at full output
Maximum recommended battery size:
For recharging: Up to 72 Amp-Hours
Maintenance only: Up to 144 Amp-Hours
Physical Dimensions:
Height: 3.5 in. (8.9 cm.)
Width: 6.4 in. (16.3 cm.)
Depth: 2.1 in. (5.3 cm.)
Weight: 3.5 lb. (1.6 kg)
Guest Model 2606A Charging Metho
FCC Class B EMC Notice
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to case harmful interference in which case
the user will be required to correct the interference at his own expense.