Making
the
DC
connections
Two
alternative
methods
for
making
the
DC
connections
are:
I.
connecting
the
DC
positive
(+)
outputs
of
the
charger
to
the
battery
connections
on
your
battery
switches
or
2.
connecting
the
DC
positive
(+)
outputs
of
the
charger
to
the
output
posts
of
your
battery
isolator.
(Do
NOT
connect
the
charger’s
outputs
to
an
isolator’s
inputs.)
These
methods
are
only
recommended
if
your
281
SM
will
be
mounted
much closer
to
your
battery
switches
or
battery
isolator, than
it
will
be
to
your
batteries.
For
sample
diagrams
of
these
types
of
installations,
refer
to
Guest
document
1-21681.
This
is
included with
all
Guest
battery
switches
and
isolators,
and
is
available
on
request.
1.
Use the
following
table
to
determine
the gauge
(thickness)
of
the
wire
you will need to
carry
the current
from the
charger
to your batteries
safely
and
efficiently.
Recommended
DC
wire
sizes
Length
of
wire,
(in
feet)
as
measured
from
the
battery
charger
to
the
farthest battery
and
back
to
the
charger
(maximum
3%
voltage
drop)
10
l4ga. l2ga.
lOga.
tOga.
tOga.
6ga.
115
I2ga.
lOgs. lOga.
Sga.
8ga. 6ga. 6ga.
I
20
10
ga.
10
ga.
8
ga.
6
ga.
6
ga.
6
ga.
4
ga.
25
10
ga.
8
ga.
6
ga.
6
ga.
6
ga.
4
ga.
4
ga.
30
10
ga.
8
ga.
6
ga.
6
ga.
4
ga.
4
ga.
2
ga.
40
8
ga.
6
ga.
6
ga.
4
ga.
4
ga.
2
ga.
2
ga.
50
6
ga.
6
ga.
4
ga.
4
ga.
2
ga.
2
ga.
1
ga.
from
Section
E9,
table
Vii
of
the
American
Boat
and
Yacht
Council
(ABYC)
standards
and
Recommended
Practices
for
5mail
Craft’
2.
Find
a
path
for
the DC
wires
between
the
chargt~rand
your
batteries.
Remember
to
route
the
wires
away
from
hot
surfaces
or
other
areas
where
the
wires could
be
damaged.
Make
sure
you will
be
able
to fasten
a
ceVble
tie
to
a
solid surface
at
least every
18
inches
throughout
the
length
of
the
wires
to support them according to
ABYC
standard E-9.
1
5h.
-8-
Planning
the
DC
connections
(cont.)
This
is
the
most
common
type
of
battery
charger
installation:
Diagram
2
red
Two
12
volt
batteries
Max.
amps
10
feet
15
feet 20 feet
25
feet
30
feet
--~----
12
volt
DC
negative
(-)
ground
50
feet
40
feet
8
ga.
-7-