APS-7000 Programming Manual
118
[:SOURce]:SIMulation:NORMal<1|2>:FREQuency
{<NR2>|MINimum|MAXimum}
[:SOURce]:SIMulation:NORMal<1|2>:FREQuency?
[MINimum|MAXimum]
Parameter/Return
parameter
Frequency of abnormal step
:SIM:NORM1:FREQ 60
Sets the frequency to 60Hz.
[:SOURce]:SIMulation:NORMal<1|2>
:PHASe:STARt:ENABle
Enables/Disables the ON Phs parameter of the
normal1 or normal2 step for the Simulation mode.
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STARt:E
NABle {<bool>|OFF|ON}
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STARt:E
NABle?
Parameter/Return
parameter
:SIM:NORM1:PHAS:STAR:ENAB 1
Enable the ON Phs.
[:SOURce]:SIMulation:NORMal<1|2>
:PHASe:STARt[:IMMediate]
Sets or queries the ON Phs parameter of the
normal1 or normal2 step for the Simulation mode.
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STARt[:I
MMediate] {<NR2>|MINimum|MAXimum}
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STARt[:I
MMediate]? [MINimum|MAXimum]