REMOTE CONTROL
59
Parameter
<NR1>
0~9 (SIM0 ~ SIM9).
MIN
0
MAX
9
Example
:DATA:SIM:REC 1
Loads the data from SIM1.
:DATA|TRACe:SIMulation:STORe
Set
Description
Saves the simulation data. This command is the
equivalent saving a simulation memory in
Simulation mode (SIM0 ~ SIM9).
Syntax
:DATA|TRACe:SIMulation:STORe
{<NR1>|MINimum|MAXimum}
Parameter
<NR1>
0~9 (SIM0 ~ SIM9).
MIN
0
MAX
9
Example
:DATA:SIM:STOR 1
Saves the data from SIM1.