EasyManua.ls Logo

GW Instek APS-7100 - Warning Status Register Group

GW Instek APS-7100
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE CONTROL
135
Warning Status Register Group
Overview
The Warning Status Register Group is a secondary
protection status register for the supply output.
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Output OFF after RMS current limiter is activated
Output OFF after peak current limiter is activated
Always 0
Condition
0
PTR/NTP Event Enable
2
4
5
7
9
10
11
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Warning Status Register
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
Logical OR
To Status Byte Register
STATus:WARNing:CONDition? STATus:WARNing:EVENt?
STATus:WARNing:NTRansition <NRf>
STATus:WARNing:NTRansition?
STATus:WARNing:PTRansition <NRf>
STATus:WARNing:PTRansition?
STATus:WARNing:ENABle <NRf>
STATus:WARNing:ENABle?
Not Used 8
Not Used 12
Not used 14
RMS current limiter is
operating
13
Output overcurrent (RMS) 1
Output overcurrent (Peak) 3
OT (Over Temperature) 6
Bit Summary
Event
Bit #
Bit
Weight
Output overcurrent (RMS)
Output RMS overcurrent has
been tripped.
1
2
Output over-current (Peak)
Output peak over-current has
been tripped.
3
8
OT (Over Temperature)
6
64
Output OFF after peak current
limiter is activated
10
1024

Table of Contents