GRS-6052A/6032A OSCILLOSCOPE
USER MANUAL
88
Waveform Data Commands
Dump Waveform
WA?
Dump channel 1 waveform data
WB?
Dump channel 2 waveform data
WC-D?
Dump 2 recalled waveform data
W0-9?
Dump REF 0-9 waveform data
Syntax
WA?
W5?
Note: GRS 60x2A can’t return waveform data in real-time mode or in roll
mode( 100s/DIV to .2s/DIV) of storage mode.
GRS-6052A/6032A OSCILLOSCOPE
USER MANUAL
89
Menu Commands
Smooth
M 1 = Parameters (3Bytes)
M1?
Sets or queries the waveform smooth function
Syntax
M1=001
M1?
Arguments
Parameters:
000Disable Smooth function 001Enable Smooth function
Average
M 2 = Parameters (3Bytes)
M2?
Sets or queries the waveform average function.
Syntax
M2=006
M2?