5. SPECIFICATIONS
Measurement Parameters:
Inductance (L
s
/L
p
)
*
, Capacitance (C
s
/C
p
), Resistance (R
s
/R
p
), Dissipation (D),
Quality Factors (Q), Equivalent Series Resistance (ESR)
and Equivalent Parallel
Resistance (EPR), Impedance (|Z|), Phase angle of Impedance [degree] (?).
Measurement Models:
Four kinds of measurement model can be selected. Two measurement
parameters measured and displayed simultaneously.
R/Q, C/D, C/R, L/Q, Z/?, L/R.
Display Ranges:
Primary Display
Inductance (L) : 0.00001mH
99999H
Capacitance (C) : 0.00001pF
99999μF
Resistance (R) : 0.00001Ω
99999kΩ
Absolute of Impedance (Z) : 0.00001Ω
99999kΩ
Secondary Display
Dissipation factor (D)
+
: 0.0001
9999
Quality factor (Q)
***
: 0.0001
9999
Phase angle of Impedance (degree)
: -180.00°
180.00°
Equivalent Series Resistance (ESR)
+
: 0.0001Ω
9999 kΩ
Equivalent Parallel Resistance (EPR)
+
: 0.0001Ω
9999 kΩ
Dissipation factor (D)
+
in ppm : 1 ppm
9999 ppm
*s=series, p=parallel, ESR=Rs
**
with R
***
with L or R
+
with C
Note: Only LCR-821 has Z/ ? and L/R measurement parameter.
LCR-800 Series User Manual
37
Quality factor (Q)
**
in ppm : 1 ppm
9999 ppm
DELTA % : 0.00001%
99 999%
If any of these quantities is negative, the “-“ negative indicator is displayed
Accuracy:
R, L, C, Z : 0.05%(Basic)
D, Q, ? : .0005(Basic)
*LCR-816/826/827/829/821 is one fold less accuracy than LCR-817/819.
(LCR -816/826: 0.1%, LCR -827/829/821: 0.1%, LCR-817/819: 0.05%)
Test Frequency:
There are 504 test frequencies between 12Hz and 200kHz that can be selected
by using keypad for LCR -821. The frequency range of LCR-
819/829 covers
from 12Hz to 100kHz (total test frequencies: 504 points) , LCR-817/82
7 covers
from 12Hz to 10kHz (total test frequencies: 489 points), LCR-
816/826 covers
from 100Hz to 2kHz (total test frequencies: 16 points).
Measurement Displays:
The measured results can be shown on the LCD monitor in three ways:
:
1.
VALUE
The measured quantities of R/Q, C/D, C/R, L/Q, Z/?, L/R.
*The resolution of primary display (L, C, R, R or Z) is to be
five
digits.
*The resolution of secondary display (D, Q, R with C,
or R with
L) is to be four digits.
*The resolution of secondary display (?) is to be
2 digits after
decimal dot.
2.
DELTA %
:
The DELTA% shows the percent deviation of the measured L,
C, R or Z
value from a saved NOMINAL VALUE. The sign of
deviation is indicated.
:
3.
DELTA
The LCR difference is similar to the DELTA% except that t
he
deviation is shown in suitable units (ohms, henries, etc.)
Measurement Speed (LCR-816/817/819/821):
SLOW
MEDI
FAST
:
:
:
896ms
286ms
135ms