APPENDIX
163
Socket Server
Enable/Disable
F-57
1 = Enable
Web Server
Enable/Disable
F-59
1 = Enable
Web Password
Enable/Disable
F-60
1 = Enable
UART setting
Setting
Default Setting
UART Mode
F-70
1 = Enable
UART Baudrate
F-71
7 = 115200
UART Data Bits
F-72
1 = 8 bits
UART Parity
F-73
0 = None
UART Stop Bit
F-74
0 = 1 bit
UART Transmission
Control Protocol
F-75
0 = SCPI
UART Address
F-76
30
UART Multi-Drop control
F-77
0 = Disable
Power On Configuration
setting
Setting
Default Setting
CV Control
F-90
0 = Panel control (local)
CC Control
F-91
0 = Panel control (local)
Output Status when
Power ON
F-92
0 = Safe Mode
Master/Slave
F-93
0 = Independent
External Out Logic
F-94
0 = High ON
Monitor Voltage Select
F-96
0 = 5V
Control Range
F-97
0 = 5V[5kΩ]
External Output Control
Function
F-98
0 = OFF

Table of Contents