41 
Item S5120-28C-EI
S5120-24P-EI
S5120-52C-EI S5120-48P-EI
Interface card 
models supported 
(optional) 
The S5120-24P-EI and S5120-48P-EI do not support optional interface cards. 
The S5120-28C-EI and S5120-52C-EI can support two interface cards of the following 
models: 
•  Short-haul 2-port 10GE CX4 interface card (LSPM1CX2P) 
•  2-port 10 GE SFP+ interface card (LSPM2SP2P) 
•  2-port 10 GE XFP interface card (LSPM1XP2P) 
•  1-port 10 GE XFP interface card (LSPM1XP1P) 
•  2-port GE SFP interface card (LSPM2GP2P) 
•  2-port 1/10GBase-T interface card (LSPM1XGT2P) 
Power receptacle 
types and quantity 
1 AC power receptacle and 1 RPS power receptacle 
Input 
voltage 
AC 
•  Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz 
•  Input voltage range: 90 VAC to 264 VAC @ 47 Hz to 63 Hz 
RPS 
The rated voltage range is 10.8 VDC to 13.2 VDC. Use the external RPS power supply 
units recommended by H3C only. For relevant information, see the RPS user manuals 
and RPS Ordering Guide for H3C Low-End Series Ethernet Switches. 
Minimum power 
consumption 
36 W  35 W  55 W  54 W 
Maximum power 
consumption 
103 W  62 W  145 W  110 W 
Cooling system  4 fans 
Operating 
temperature 
0°C to 45°C (32°F to 113°F) 
Relative humidity 
(noncondensing) 
10% to 90% 
 
Table 8 The S5120-EI Switch Series technical specifications (2) 
Item 
S5120-28C-PWR-EI
S5120-52C-PWR-EI 
PoE model  PoE+ model
PoE model
PoE+ model
Dimensions (H × W 
× D) 
43.6 × 440 × 420 mm  
(1.72 × 17.32 × 16.54 in) 
43.6 × 440 × 420 mm  
(1.72 × 17.32 × 16.54 in) 
Weight  < 7.0 kg (15.43 lb)
< 7.0 kg (15.43 lb)
< 7.5 kg (16.53 lb)  < 7.5 kg (16.53 lb)
Management port  1 console port, on the front panel 
GE ports 
24 × 10/100/1000Base-T auto-sensing 
Ethernet port (support PoE) 
4 × 1000Base-X SFP port 
48 × 10/100/1000Base-T auto-sensing 
Ethernet port (support PoE) 
4 × 1000Base-X SFP port 
The last four 10/100/1000Base-T Ethernet ports and the four SFP ports comprise four 
combo interfaces. For each combo interface, either the SFP port or the corresponding 
Ethernet port can be used at a time. For the combo interface mapping relationship, 
see Table 11.