The MIPs of MD_B are designed on Device C, and are configured on all ports. You should configure
the MIP generation rule as default.
Configure CC to monitor the connectivity among all the MEPs in MD_A and MD_B. Configure LB to
locate link faults, and use the AIS function to suppress the error alarms reported.
After the status information of the entire network is obtained, use LT, LM, one-way DM, two-way DM,
and TST to detect link faults.
Figure 6 Network diagram
Configuration procedure
1. Configure a VLAN and assign ports to it:
On each device shown in Figure 6, c
reate VLAN 100 and assign ports GigabitEthernet 1/0/1
through GigabitEthernet 1/0/4 to VLAN 100.
2. Enable CFD:
# Enable CFD on Device A.
<DeviceA> system-view
[DeviceA] cfd enable
Enable CFD on Device B through Device E using the same method.
3. Configure service instances:
# Create MD_A (level 5) on Device A, create MA_A, which serves VLAN 100, in MD_A, and
create service instance 1 for MD_A and MA_A.
[DeviceA] cfd md MD_A level 5
[DeviceA] cfd ma MA_A md MD_A vlan 100
[DeviceA] cfd service-instance 1 md MD_A ma MA_A
Configure Device E as you configure Device A.
# Create MD_A (level 5) on Device B, create MA_A that serves VLAN 100, in MD_A, and then
create service instance 1 for MD_A and MA_A. In addition, create MD_B (level 3) and MA_B that
serves VLAN 100, in MD_B, and then create service instance 2 for MD_B and MA_B.
[DeviceB] cfd md MD_A level 5
[DeviceB] cfd ma MA_A md MD_A vlan 100
[DeviceB] cfd service-instance 1 md MD_A ma MA_A