DOC012.97.90371
LZV902
DR 6000
03/2012, Edition 1
User Manual en
Manual del usuario es
Manuel d'utilisation fr
ユーザー マニュアル ja
사용 설명서 ko
Manual do utilizador pt
用户手册 zh

Questions and Answers

  • S
    Sean BradshawSep 2, 2025
    What does 'Error Selfcheck stopped. Hardware error' mean on Hach Measuring Instruments?
    • J
      James NewtonSep 2, 2025
      If the Hach Measuring Instruments displays 'Error Selfcheck stopped. Hardware error', it indicates an electronic defect. Contact technical support and provide the error number.
  • S
    Sean DonovanSep 14, 2025
    What to do if Hach Measuring Instruments displays 'Web server cannot be reached'?
    • E
      emilywangSep 14, 2025
      If the Hach Measuring Instruments displays 'Web server cannot be reached', it means the Viper homepage cannot be reached. Try the connection again later.
  • M
    Marcus DelgadoAug 31, 2025
    What to do if Hach Measuring Instruments displays 'System check incorrect!'?
    • B
      bporterAug 31, 2025
      If the Hach Measuring Instruments displays 'System check incorrect!', it means the measurement of air values failed. Switch the instrument off and then back on again. If the system check is still unsuccessful, contact technical support.
  • P
    Phillip RodriguezSep 16, 2025
    What to do if Hach LZV902 displays 'Temperature too high. Measurement not possible!'?
    • N
      Nicholas WilkersonSep 16, 2025
      If the Hach Measuring Instruments displays 'Temperature too high. Measurement not possible!', switch off the instrument and allow it to cool for a few minutes. If necessary, move it to a cooler place.
  • J
    John MillerSep 15, 2025
    What does 'Shelf life exceeded! Use chemicals?' mean on Hach LZV902?
    • A
      Allison BaileySep 15, 2025
      If the Hach Measuring Instruments displays 'Shelf life exceeded! Use chemicals?', the analysis may be erroneous. Use new chemicals.
  • M
    Michael McdowellSep 23, 2025
    What does 'Control range not reached!' mean on Hach LZV902 Measuring Instruments?
    • R
      robinkingSep 23, 2025
      If the Hach Measuring Instruments displays 'Control range not reached!', this is a warning notice indicating that the control limit set was not reached.
  • S
    Steven RobertsAug 27, 2025
    What to do if Hach LZV902 Measuring Instruments says 'File for instrument update is faulty'?
    • M
      Michael RiceAug 28, 2025
      If the Hach Measuring Instruments indicates that the file for the instrument update is faulty, it means there was an error during the update. Save the update file again and repeat the procedure.
  • S
    Shane GainesAug 27, 2025
    What does 'Fault Clean cuvette!' mean on Hach Measuring Instruments?
    • B
      brookefoxAug 27, 2025
      If the Hach Measuring Instruments displays 'Fault Clean cuvette!', it indicates that the cuvette is dirty or there are undissolved particles in it. Clean the cuvette and allow any particles to settle before proceeding.
  • G
    gtaylorAug 26, 2025
    What to do if Hach LZV902 Measuring Instruments says 'Over measuring range'?
    • J
      Joseph OlsonAug 26, 2025
      If your Hach Measuring Instruments indicates that you are over the measuring range, it means the measured absorbance is above the calibration range of the test. To fix this, dilute the sample and measure it again.
  • M
    Michael SchneiderAug 25, 2025
    What to do if Hach LZV902 Measuring Instruments displays 'Concentration too high!'?
    • M
      Mark SmithAug 26, 2025
      If the Hach Measuring Instruments displays 'Concentration too high!', it means the calculated concentration is higher than 999999. Dilute the sample and measure again to resolve this issue.

Hach LZV902 Specifications

General IconGeneral
Accuracy±5% of reading or ±5 mg/L (ppm), whichever is greater
Operating Temperature0 to 60 °C (32 to 140 °F)
Range0 - 4000 mg/L (ppm)
Output4-20 mA, RS-485 Modbus
Measurement Range0 - 4000 mg/L (ppm)
Wetted Materials316 stainless steel