226
Smart Power
Press for a 3rd time, it displays default for the rst time (previous setting will be displayed if there is setting
before). Then the hour position and “OFF” are ashing;
Pressing a 4th time, the minute position and “OFF” are ashing;
Pressing a 5th time, it displays default for the rst time (previous setting will be displayed if there is setting
before). Then the hour position and “ON” are ashing;
Pressing a 6th time, the minute position and “ON” are ashing;
Pressing a 7th time, it displays default for the rst time (previous setting will be displayed if there is setting
before). Then the hour position and “OFF” are ashing;
Pressing a 8th time, the minute position and “OFF” are ashing;
Pressing a 9th time, cancel the setting.
(3) Relation to other buttons when timer is set.
Press the key or key to exit the current setting, press them again to operate the function accordingly;
Press the
(ON/OFF) key can exit the timer setting and power ON/OFF directly. If there is a timer before, the
wired controller will operate by following the previous setting. If not, the wired controller will have no timer operation.
Swing
(1) If Sw7 is off (default): only Up/Down swing is available.
Press SET key to enter function circulation, Up/Down swing icon ashing, then press SET key again to conrm with
swing icon statically displaying. If swing function is set, execute the above operation to cancel.
(2) If Sw7 is on: Up/Down swing and Left/Right swing are available.
Press SET key to enter function circulation, Left/Right swing icon ashing, then press Up/Down key to enter Up/
Down swing, with Up/Down swing icon ashing. Press SET key again when swing icon ashing to conrm, with
swing icon statically display. If swing function is set, execute the above operation to cancel.
(3) If connecting to the salve wired controller, Sw7 dip code of master and slave wired controllers should be set the
same and should match the actual wired controller unit.
Sleeping
(1) Press
key to enter function setting, press to the sleeping icon “ ” and it will ash, the sleeping time
will display by the
which is on the top-right corner. Press Time key to enter sleeping time setting. “OFF” and
sleeping icon are ashing. Press
to adjust the sleeping time by 0.5h once, the range of sleeping time is from 0.5h
to 72h. After the adjustment, press key again to conrm the operation. “OFF” and sleeping icons are statically
displayed.
(2) During sleeping icon is ashing, pressing key instead of key, the wired controller will take the converse
operation of previous sleeping state. If there is sleeping set, cancel it; if not, come into the setting operation.
(3) If power off is executed during sleeping, the sleeping function is cancelled at the same time; there is no display
when powered on again. It needs to be reset if any requirement.
(4) In sleeping set or modication state, if there is no operation in 10 seconds, it will keep previous state, and the
setting or modication is invalid this time.
(5) Under sleeping and timer setting state, it will display setting time respectively; when setting simultaneously, it
will display the prior executed time. When timer off is executed rst, sleeping function will be cancelled and when
sleeping is executed rst, then timer off function will be operated after that.
(6) Under function setting state, it will exit function setting state by pressing or key.
(7) If set sleeping time to 1 hour, it will display on the interface.
(8) Sleeping time and timer on should not be set at the same time.
(9) When setting sleeping function, press ON/OFF key to quit sleeping set and turn off unit.
Heat Reclaim Ventilation Function
(1) Press key to enter function setting, press to the heat reclaim ventilation icon “ ” and it will ash, press
key again to conrm the operation. The above operation can cancel the heat reclaim ventilation function if heat
reclaim ventilation function has been set.
(2) After setting heat reclaim ventilation function, it is switched off together with off commend from wired controller.
Heat reclaim ventilation function is kept once the unit is switched on again.