Super Match
Item Model 3U24GS2ERA
Function —— Cooling Heating
Rating capacity W 6900 7000
Heating pdesign(-10
℃
) W 5300
Rated power input (indoor + outdoor) W 1920 1870
Rated current input (indoor + outdoor) A 8�35 7�9
EER / COP W/W 3�6 3�74
SEER / SCOP W/W 3�47 3�61
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 8200 9000
Maximum power input (indoor + outdoor) W 3100 3100
Power source —— 1PH, 220-230V~, 50/60Hz
Max. running current (indoor + outdoor) A / A 13�5 13�5
Power facor(under rating power input) —— 99% 99%
Fuse size (recommended size) A 25
Outdoor unit
Compressor
Model / Manufacture —— SNB172FJGMC/ MELCOM
Oil charge and type —— 600CC, FV 50S
Type —— Twin Rotary (DC inverter)
Number —— 1
Fan
Type × Number —— Axial × 1
Speed r/min High 860
Motor output/input power W 80/100
Air-ows (H/M/L) m³/h about 2500
Heat exchanger
Type / Diameter mm TP2M / 7.94
row —— 2
Face area m² about 0.52
Dimension
(WxDxH)
External mm 940/345/730
Package mm 1005/423/815
Refrigerant control method —— PMVs
Defrosting method —— Automatic by reversible cycle
Crankcase heater power W none
Noise level
Sound power level dB(A) 65
Sound pressure level dB(A) 54
Weight Net / Shipping kg / kg 53/56
Piping
Refrigerant
Type / Charge kg R410A / 2�1
No need to recharge m 30
Recharge g/m 20
Pipe
Liquid mm 3* Φ6.35
Gas mm 3* Φ9.52
Connecting method —— Flared
Between I.D &O.D
Drop between IU & OU m ≤7.5
Piping length between IU & OU m ≤10
Total liquid piping length m ≤30
Drop between indoor units m ≤1
Max. drop between IU &OU m 15(indoor unit lower than outdoor unit)
Max. drop between IU &OU m 15 (indoor unit higher than outdoor unit)
Max. drop between indoor units m 5
Max. piping length between IU & OU m 25
Max. total length m 60