Super MatchSuper Match
Item Model 4U30HS2ERA
Function —— Cooling Heating
Rating capacity W 8200 9600
Heating pdesign(-10
℃
) W 7100
Rated power input (indoor + outdoor) W 2250 2550
Rated current input (indoor + outdoor) A 9�8 11�1
EER / COP W/W 3�65 3�76
SEER / SCOP W/W 3�57 4�0
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 9800 10500
Maximum power input (indoor + outdoor) W 3800 3800
Power source —— 1PH, 220-230V~, 50/60Hz
Max. running current (indoor + outdoor) A / A 16�5 16�5
Power facor(under rating power input) —— 99% 99%
Fuse size (recommended size) A 25
Outdoor unit
Compressor
Model / Manufacture —— TNB220FLHMC-L / MELCOM
Oil charge and type —— 870CC/ FV50S
Type —— Twin Rotary (DC inverter)
Number —— 1
Fan
Type × Number —— Axial × 1
Speed r/min High 860
Motor output/input power W 100/125
Air-ows (H/M/L) m³/h about 3500
Heat exchanger
Type / Diameter mm TP2M / 7.0
row —— 2
Face area m² about 0.75
Dimension
(WxDxH)
External mm 948/340/840
Package mm 1040/430/1000
Refrigerant control method —— PMVs
Defrosting method —— Automatic by reversible cycle
Crankcase heater power W none
Noise level
Sound power level dB(A) 66
Sound pressure level dB(A) 56
Weight Net / Shipping kg / kg 76/87
Piping
Refrigerant
Type / Charge kg R410A / 3�2
No need to recharge m 40
Recharge g/m 20
Pipe
Liquid mm 4* Φ6.35
Gas mm 3* Φ9.52+1*Φ12.7
Connecting method —— Flared
Between I.D &O.D
Drop between IU & OU m ≤7.5
Piping length between IU & OU m ≤10
Total liquid piping length m ≤40
Drop between indoor units m ≤1
Max. drop between IU &OU m 15(indoor unit lower than outdoor unit)
Max. drop between IU &OU m 15 (indoor unit higher than outdoor unit)
Max. drop between indoor units m 5
Max. piping length between IU & OU m 25
Max. total length m 70