13
Capsule X is designed to be as free from maintenance as possible,
but the following can help keep your Capsule X in top condition.
Blockages
All vacuums block from time to time. With Capsule X most blockages can be
fixed by simply changing the Dust Pouch and using Boost mode to suck through
any blockages.
In the event this is unsuccessful check the Extension Tube and Motor Brush Head
for remaining blockages and remove these by hand. The use of sharp tools may
damage Capsule X and invalidate the warranty.
Motor Brush Head
Maintenance
Periodically, hair can become wrapped around the brush roll and should be removed
to maintain peak performance.
4. The brush roll can then be completely
removed.
5. Hair can be trimmed clear with a pair
of scissors.
6. Ensure all parts are clear of hair and
obstructions. Parts should reassemble
without being forced.
7. Reinsert brush roll and turn endcap
clockwise to secure.
1. Remove the Motor Brush Head from
both the Capsule X unit and the
Extension Tube in order to isolate it
from any power source.
2. Unlock the endcap (A) by turning it
anticlockwise.
3. Turn until the brush can be withdrawn
A