EasyManua.ls Logo

Hantek DSO 1202B - Trigger and Input Specifications

Hantek DSO 1202B
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
DSO1000B Series HandHeld Oscilloscope User Manual 67
Vertical
A/D Converter
8-bit resolution,
each channel sampled simultaneously
VOLTS Range 2mV/div to 5V/div at input BNC
Position Range
2mV/div to 200mV/div, ±2V
>200mV/div to 5V/div, ±50V
Analog Bandwidth in
Normal and Average
modes at BNC or with probe, DC
Coupled
2mV/div to 20mV/div, ±400mV
50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V
5V/div, ±50V
Selectable Analog Bandwidth Limit,
typical
20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
Rise Time at BNC, typical
DSO1062B DSO1102B DSO1202B
<5.8ns 3.5ns <1.8ns
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 5V/div to
10mV/div
±4% for Normal or Average acquisition mode, 5mV/div
to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
Measurement Type: Average of 16 waveforms with
vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when
10mV/div or greater is selected
Measurement Type: Average of 16 waveforms with
vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of
vertical position + 0.2div]
Add 2mV for settings from 2mV/div to 200mV/div; add
50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms
acquired under same setup and ambient conditions
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Trigger
Trigger Sensitivity
(Edge Trigger Type)
Coupling Sensitivity
DC
Source
DSO1062B
DSO1102B
DSO1202B
CH1
CH2
1div from DC to
10MHz;
1.5div from 10MHz to
1.5div from 10MHz
to 100MHz;
2div from 100MHz to

Table of Contents