E8.4.6
Boom
[0, 1, 2]
sensors
Default: 1.
This is the number of boom fold sensors
present.
For CM: Choose 1 or 2
For NAV: Choose 0
E8.4.7
Error print
[Yes]
Prints last 3 hazardous situations and shows
Alteration log changes.
E8.4.8
Minimum
[6.0 m]
radius
Default = 6.0 m for NAV.
CM Minimum turning radius allowed for the
trailer.
Tank size 3200 L= 6.5, 4400 L= 7.0, 6600
L= 9.0.
Increase to achieve a soft-stop (prevent
bottoming out) on trapeze cylinders.
E8.4.9
Half steer
[No,Yes]
Default = No
SPC/SPZ, only active with 2 boom sensors
E8.4.10
Safety
factor
[100%]
Raising this value increases captiousness.
Default is 100% for a CM 4400.
For CM 3200, use 90%
For CM 6600, use 120%.
Use steps of 10% as a guide to changes.
E8.4.11
Boom type
[L, M, H]
Not active
Default: M
Classification of boom type. Light, Medium
or Heavy.
E8.5
Misc.
E8.5.1
Foot switch
[Disable, On/off level, On/off pulse]
For remote ON/OFF of main switch, it allows
the use of other switch systems.
See “Foot pedal” section.
E8.5.2
Rate deviation
[Step size: XX %]
Default is 10%.
Can be altered.
If set at 0%, this allows 3 rates to be set up
in menu 1.1.
E8.5.3
Capacity left
[Distance, Area]
Affects readout from Display icon. Will show
distance or area remaining.