EasyManuals Logo

Hardi MASTER TWIN STREAM User Manual

Hardi MASTER TWIN STREAM
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
GB 04 02 MA
Description
Description and rDescription and r
Description and rDescription and r
Description and r
ee
ee
e
vievie
vievie
vie
w ofw of
w ofw of
w of
the the
the the
the
MASTER sprMASTER spr
MASTER sprMASTER spr
MASTER spr
aa
aa
a
yy
yy
y
erer
erer
er
TT
TT
T
ankank
ankank
ank
The tank (A), made of impact-proof and chemical
resistant polyethylene, has a purposeful design with no
sharp corners for easy cleaning. Nominal contents: 800,
1000 or 1200 litres.
A large, easy to read tank contents indicator (B) is
placed in front of the tank.
The filling hole (C) and a footboard (D) is placed at the
right hand side of the sprayer. This ensures an easy
access for the filling of sprays, cleaning of the tank, etc.
Rinsing tank(s) (E) are optional equipment.
Clean water tank (F) is optional equipment.
HARDI-FILLER (G) is optional equipment.
FF
FF
F
rr
rr
r
ameame
ameame
ame
Very strong and compact frame which also has a strong
chemical and weather resistant electrostatic lacquer
coat. Screws, nuts, etc. have been DELTA-MAGNI
treated to be resistant to corrosion.
PumpPump
PumpPump
Pump
Diaphragm pump model 1302 or 363. The design of the
diaphragm pump is simple, with easily accessible
diaphragms and valves which ensures liquid does not
contact the vital parts of the pump.
MANIFOLD syMANIFOLD sy
MANIFOLD syMANIFOLD sy
MANIFOLD sy
stemstem
stemstem
stem
The functions of the spray circuits are operated via the
centrally situated MANIFOLD valves with colour coded
plates and pictorial symbols for easy operation (H).
OperOper
OperOper
Oper
aa
aa
a
ting unitting unit
ting unitting unit
ting unit
The sprayer is equipped with either a BK operating unit
or an EVC unit (I).
BK operating unit
The BK operating unit consists of; pressure agitator
valve, safety valve, main ON/OFF valve, pressure filter
with pressure gauge, distribution valves with pressure
equalization and HARDI-MATIC pressure control valve.
EVC unit
EVC - Electrical Valve Control. The ON/OFF is linked to
the section valves, which results in a very quick re-
sponse to ON/OFF. The operating unit is constructed of
modules and is electrically controlled via a remote
control box. The unit is fit with built-in HARDI-MATIC.
HARDI-MATIC ensures a constant volume per hectare
of the liquid (l/ha) at varying forward speed within the
same gear when the number of P.T.O. revolutions are
between 300-600 r/min.
T102-0016
H
I
T102-0015
A
E
B C
DG
F
E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi MASTER TWIN STREAM and is the answer not in the manual?

Hardi MASTER TWIN STREAM Specifications

General IconGeneral
BrandHardi
ModelMASTER TWIN STREAM
CategoryPaint Sprayer
LanguageEnglish

Related product manuals