Questions and Answers

  • J
    John BakerSep 13, 2025
    What to do if the smoke stack is stopped up in my Hardy H6?
    • T
      Tyler WilliamsSep 13, 2025
      If the smoke stack of your Hardy Wood stove is stopped up, remove the smoke stack. Check the flue out of the top of the heater, and clean both the flue pipe and the smoke stack.
  • J
    Julie LewisSep 15, 2025
    What to do if the baffle is stopped up in my Hardy H6?
    • E
      Emily McleanSep 15, 2025
      If the baffle in your Hardy Wood stove (Model H4 Only) is stopped up, remove the baffle through the fire box door, and clean the baffle and flue area.
  • X
    xhollowayNov 24, 2025
    What to do if the pump does run in my Hardy H6 Wood stove?
    • C
      Casey LongNov 25, 2025
      If the pump in your Hardy Wood stove is running but there are still issues, consider these troubleshooting steps. First, check the 24-volt transformer at the existing central unit; if 115/120 volts is being supplied to the primary side, check for 24 volts on the secondary; if 24 volts is not present, replace the transformer. Next, inspect the wall thermostat inside your home; remove the cover, check for 24 volts, level the mounting base, blow dust from the sensing bimetal, and adjust the heat anticipator. Then, bypass the low-temperature sensor by removing the wires and connecting them to each other; if the pump runs, replace the low-temperature sensor. Finally, check the pump relay terminals #7 & #8 for 24 volts; if 24 volts is present, use an ohmmeter to check contacts by connecting it t...

Summary

Introduction to the Hardy Heater

Essential Safety Precautions

Highlights critical safety precautions and warnings for operating the heater safely.

Outdoor Furnace Best Burn Practices

Details recommended practices for efficient and safe burning of the outdoor furnace.

General Information

Heater Specifications

Lists key specifications including fuel type, electrical rating, clearances, and water capacity.

Heater Installation

Heater Location and Pad Requirements

Specifies recommended placement and site preparation for the outdoor wood burning heater.

Connecting to Different Heating Systems

Domestic Hot Water Integration

Heater Operation and Performance

Firing the Heater Safely

Instructions on how to properly start and maintain a fire in the heater.

Maintaining Optimal Water Temperature

Guidance on setting and maintaining the correct water temperature for efficient operation.

Resolving Improper Burning Issues

Addresses common problems related to improper burning and their solutions.

Service and Troubleshooting

Troubleshooting Common Problems

A detailed guide to diagnosing and resolving various operational complaints and issues.

Hardy H6 Specifications

General IconGeneral
Heating Capacity1, 500 - 2, 500 sq ft
Efficiency75%
Firebox MaterialSteel
EPA CertifiedYes
Blower IncludedOptional