To Previous Page IconTo Previous Page
Loading...
26
3-90-08101R23_06/13
8. Turn the Temperature Dial on the furnace control to
“NORMALSETTING”.
9.Turn Mode Selectorto“AUTOMATIC”.Thiswillstartthe
lightingprocessifthetemperatureatthewallcontrolis
lessthanthesettemperatureonthedial.
This unit is more than just an automatic ignition pellet
furnace.Theautomaticsystemwillallowtheresizeto
beadjustedtomatchtheheatingneedsandevenputthe
reoutifnecessary.Ifheatisneededafterthereisout,
thefurnacewillautomaticallyre-igniteandadjustthere
sizetomatchtheheatingneed.
10. Fill the hopper with pellets and remove ashes as
required.
Type of Fuel
Usepelletizedwoodonly.Note:Thelowertheashcontent
ofthepelletsthelesscleaningthatwillbeneededoftheheat
exchangersurfaces.Thecleanerthesesurfacesarekept,
themoreefcientthefurnacewillbe.
NOTE: Do not burn garbage, gasoline, naphtha, engine
oil, or other inappropriate materials in the PF100.
Store pellets in the manufacturer’s wrapping until needed
to prevent pellets from absorbing moisture. Do not store
fuel within the appliance installation clearances, or within
the space required for fueling, ash removal, and other
routine maintenance operations.
Operation
Fig. 53
Fig. 54
This is the Control setting that will allow the Wall Control to
function.