A-20 888-2595-001 12/20/11
WARNING: Disconnect primary power prior to servicing.
ZX Series
Appendix A - FM Web Remote Option
STEP 2 Note log entry time stamp as compared to quality external clock.
STEP 3 Access configuration page and recalibrate on-board time to correct
value, as desired.
STEP 4 Repeat steps 1 and 2 several hours or several days later.
STEP 5 Note if on-board clock has lost or gained seconds relative to quality
external clock.
STEP 6 Extrapolate rate of gain/loss to 24 hour time period. e.g. 1 sec lost in 12-
hour period = +2 second adjustment required per 24-hour period.
STEP 7 Increment/decrement SEC/DAY time adjustment field on configuration
page.
STEP 8 Recalibrate on-board time to correct value as desired.
STEP 9 Procedure complete.
A.5.6 Use Microchip Discoverer Utility
Purpose: The USB flash drive supplied with the web remote contains a small
application called Microchip Ethernet Discoverer. This program can be useful for
locating a web remote with an unknown IP address, but is limited to detecting only web
remotes connected to the same subnet. (1:1 PC connection or sharing same router)
Special tools: Microchip Ethernet Discoverer.exe
Figure A-7 Web discover results window.