2-2 RefRigeRation / electRical
P/N 0387183_V
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • WWW.HUSSMANN.COM
As shown in Figure 2-3, rotate and center the shroud
over the refrigeration outlet foam pad.
Seal this outlet thoroughly. Seal both the inside
and the outside. We recommend using an expanding
polyurethane foam insulation. Cover foam with
silicone to prevent water from entering foam.
Optional Internal Top Piping Connections
A shroud should be used to seal outside pipe
penetrations at the top of the merchandiser. Position
the shroud over the case piping before making the
final connection.
Once all connections are made and insulation has
been applied to the piping, run a bead of sealant
around the bottom of the shroud. Put the shroud into
position and attach with six screws.
In the event the shroud was not placed over the
piping prior to final connection, the shroud
can be cut (carefully) and then installed with
adhesive holding the shroud in place on top of the
merchandiser.
After connections have been made, seal this outlet
thoroughly. Seal both the inside and the outside.
We recommend using an expanding polyurethane
foam insulation. Cover foam with silicone to ensure
seal around insulation and to prevent deterioration
of foam.
Figure 2-3