USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
092596 RevA
Hayward Pool Products
620 Division Street, Elizabeth NJ 07207
Phone (908)-355-7995
www.hayward.com
HydroRite UVO3
Owner’s Manual
Model: HYD-UVO
2” Residential UV/Ozone Sanitizing System
Contents
Safety Instructions..........1
Before you Begin.............2
Installation.....................3
Operation.......................7
Maintenance...................7
FAQs.............................10
Troubleshooting............11
Replacement Parts.........12
Warranty.......................14

Other manuals for Hayward hydrorite uvo3

Question and Answer IconNeed help?

Do you have a question about the Hayward hydrorite uvo3 and is the answer not in the manual?

Hayward hydrorite uvo3 Specifications

General IconGeneral
TypeUV Disinfection System
ApplicationResidential
Lamp Life9000 hours
Inlet/Outlet Size2 inches
Operating Pressure50 psi maximum
Operating Temperature40°F to 104°F (4°C to 40°C)

Summary

IMPORTANT SAFETY INSTRUCTIONS

Follow All Safety Instructions

This product should be installed by a professional service technician or similar person qualified in electrical equipment installation.

Save Safety Instructions

Instructions for saving and retaining safety information for future reference.

Before You Begin

How HydroRite Works

Explanation of the HydroRite's UV and ozone sanitization process.

Product Specifications

Technical details including plumbing diameter, power, and operating flow range.

What's Included

List of components included in the HydroRite system package.

Tools Needed

List of tools required for the installation of the HydroRite system.

Installation Guide

Installation Overview

General overview and initial steps for installing the HydroRite unit.

Choosing Installation Location

Guidelines for selecting a suitable and safe location for the HydroRite system.

Plumbing and Mounting

Mounting the Controller

Instructions for securely mounting the HydroRite controller unit.

HydroRite System Plumbing

Details on plumbing the HydroRite system, including bypass options.

Vessel Securing and Plumbing

Procedures for securing the vessel and plumbing its inlet/outlet connections.

Head Loss and Venturi System

Information on system head loss and the venturi assembly connection.

Electrical and Vessel Connections

Electrical Wiring Connections

Guidance on making electrical connections for the HydroRite system.

Vessel Component Connections

Instructions for connecting the venturi tube, ballast cable, ozone tube, and interlock cable.

System Setup and Power

Controller Cable Connections

Connecting the flow switch and interlock cables to the HydroRite controller.

Input Power Requirements

Information on connecting the HydroRite to a GFCI protected power outlet.

Pool Water Preparation

Steps for preparing pool water chemistry before operating the HydroRite.

Operation and Maintenance Overview

Starting and Operating HydroRite

Instructions for initial startup and automatic operation of the HydroRite.

Understanding LED Indicators

Explanation of the status lights (LEDs) on the HydroRite controller.

Routine Maintenance Guidelines

General guidance for routine maintenance to ensure optimal performance.

Automatic Quartz Sleeve Cleaning

Using an automatic cleaner to maintain the HydroRite's quartz sleeve.

Manual Quartz Sleeve Cleaning

Step-by-Step Cleaning Procedure

Detailed, sequential instructions for manually cleaning the quartz sleeve.

Advanced Maintenance and Service

Sleeve Cleaning and Reassembly

Steps for cleaning the quartz sleeve and reassembling the unit.

Lamp Replacement & Winterizing

Procedures for replacing the UV lamp and winterizing the unit.

Obtaining Service Support

Information on how to get service or assistance for the HydroRite unit.

Frequently Asked Questions

Chemical Compatibility

Addresses compatibility of HydroRite with various pool chemicals.

UV Residual Effect

Discusses whether UV light leaves a residual effect in the water.

Salt Water System Compatibility

Confirms compatibility of HydroRite with salt water systems.

Filter Cleaning & HydroRite

Whether HydroRite needs to be turned off during filter cleaning.

Lamp Life & Timer Settings

Impact of pool timers on UV lamp life.

Mounting Orientation

Requirement for vertical mounting of the HydroRite unit.

Multiple Unit Installation

Possibility of using multiple HydroRite units for larger systems.

Ozone Residual Effect

Discusses the residual effect of ozone produced by the HydroRite.

Chlorine Requirement

Explains the continued need for chlorine alongside HydroRite.

Troubleshooting Common Issues

UV Lamp Not Lighting

Diagnosing why the UV lamp may not light at start-up.

UV Lamp No Longer Lit

Troubleshooting steps when the UV lamp stops working during operation.

Unit Noise Issues

Identifying causes for unusual noises from the HydroRite unit.

Vessel Cap Water Leak

Troubleshooting water leaks around the vessel cap.

No Bubbles in Vessel

Diagnosing the absence of bubbles indicating ozone generation.

Replacement Parts List

Limited Product Warranty

Controller & Vessel Warranty

Warranty period for the controller and vessel components.

Lamp & Sleeve Warranty

Warranty period for the UV lamp, quartz sleeve, and related parts.

Warranty Exclusions & Limitations

Conditions and events that are excluded from the limited warranty.