Page
50
hole
A).
Then
use
two
6-32
x
1/4"
screws
and
two
#6
lockwashers
to
mount
the
indicated
corners
of
the
circuit
board
to
spacers
BX
and
BY.
Route
the
free
end
of
the
blue
wire
coming
from
the
meter
circuit
board
as
shown.
Then
connect
the
end
of
the
wire
to
filter
circuit
board
hole
B
(S-1).
Cut
off
any
excess
wire
end.
Route
the
free
end
of
the
red
wire
coming
from
the
meter
circuit
board
as
shown.
Then
connect
the
end
of
the
wire
to
filter
circuit
board
hole
A
(S-1),
Cut
off
any
excess
wire
end.
Use
a
cable
tie
to
secure
the
blue
and
red
wires
to
spacer
BY.
Cut
off
the
excess
cable
tie.
ing
from
cable
clamp
CD
to
circuit
board
hole
E
(S-1).
Cut
both
red
power
transformer
leads
to
6"
and
both
yellow
power
transformer
leads
to
9".
Then
remove
1/4”
of
insulation
from
the
end
of
each
of
these
leads.
Tl:
Set
the
power
transformer
in
the
main
chassis
as
shown.
Then
refer
to
Detail
6-17C
and
use
1/4”
x
1"
hardware
to
secure
it
to
the
chassis.
NOTE:
To
start
each
nut
onto
its
screw,
you
may
wish
to
push
the
smaller
end
of
the
nut
starter
into
the
nut
as
shown
in
the
inset
drawing.
vA
Connect
the
free
end
of
the
large
red
wire
com-
WY
iy
NOTE:
Make
mechanically
secure
connections
when
you
connect
the
power
transformer
leads
in
the
fol-
lowing
steps.
,(%
Connect
the
green-yellow
power
transformer
;
lead
to
terminal
strip
CB
lug
1
{S-2).
WA
Conncct
either
green
power
transformer
lead
to
!
terminal
strip
CB
lug
3
(S-1).
NOTE:
A
black
wire
was
previously
soldered
to
the
eyelet
of
this
lug.
na
Connect
the
remaining
green
power
transformer
:
lead
to
terminal
strip
CB
lug
4
(S-1).
NOTE:
A
black
wire
was
previously
soldered
to
the
eyelet
of
this
lug.
amcnes)
2
Heathkit
NOTE:
When
you
solder
one
of
the
red
wires
power
transformer
Icads
to
filter
circuit
board
hole
D,
in
the
next
step,
be
careful
not
to
burn
the
insulation
on
the
nearby
black
wire.
Loosely
twist
together
(approximately
1
turn-
per-inch)
the
two
red
power
transformer
leads.
Then
connect
the
end
of
either
lead
to
filter
circuit
board
hole
D
(S-1).
The
other
red
power
transformer
lead
will
be
connected
later.
Position
the
rectifier
circuit
board
near
the
filter
cir-
cuit
board.
Then
connect
the
wires
coming
from
the
rectifier
circuit
board
as
follows:
LD
Red
wire
to
filter
circuit
board
hole
F
(S-1).
Ww
Black
wire
to
filter
circuit
board
hole
C
(S-1).
Y
Refer
to
Detail
6-17D
and
use
four
6-32
x
1-1/4"
screws,
four
3/4"
spacers,
and
four
#6
lockwash-
ers
to
mount
the
rectifier
circuit
board
and
filter
circuit
board
to
spacers
BT,
BU,
BV,
and
BW.
yf
Connect
the
end
of
the
remaining
red
power
transformer
lead
to
rectifier
circuit
board
pin
B
(S-1).
$)
Loosely
twist
together
the
two
yellow
power
transformer
leads.
Then
connect
either
lead
to
meter
circuit
board
hole
A
(S-1)
and
the
other
lead
to
hole
B(S-1).
()
Connect
the
free
end
of
the
black-white
power
transformer
lead
to
barrier
strip
RD
lug
5
(S-1).
NOTE:
Two
other
wires
were
previously
soldered
to
the
other
hole
in
this
lug.
)
Connect
the
free
end
of
the
brown-white
power
transformer
lead
to
barrier
strip
RD
lug
4
(S-1).
9
Connect
the
free
end
of
the
black
power
trans-
former
lead
‘to
barrier
strip
RD
lug
3
(S-1).
NOTE:
A
wire
was
previously
soldered
to
the
other
hole
in
this
lug.
7
y
Connect
the
free
end
of
the
brown
powcr
transformer
lead
to
barrier
strip
RD
lug
2
(S-1).
NOTE:
A
wire
was
previously
soldered
to
the
other
hole
in
this
lug.
vu