67
TROUBLESHOOTING
CHART
(Cont'd)
No
high
voltage.
None
of
the
meter
lamps
light.
1.
Lamps
PL1
through
PL4.
2.
Bridge
rectifier
D201.
1,
Diode
D301
through
D310.
2.
Capacitor
C401
through
C408.
3.
Resistor
R405
through
R409
or
A441
through
R413.
4.
Coil
L401
5.
Choke
RFC3.
6.
Parasitic
choke
PC1.
Relay
K1
does
not
activate.
1.
OPR/STBY
switch
SW1.
2.
interconnection
to
exciter.
3.
Resistor
R3.
4.
Relay
K1.
Plate
contral
has
no
effect.
1.
Band
switch
SW2A,
B,
C,
D,
or
E.
2.
Coil
L7
or
L8.
3.
Capacitor
C26, C28,
or
C29.
4,
Variable
capacitor
C27.
No
RF
output.
ALC
inoperative.
Amplifier
is
hard
to
drive.
1.
Relay
K1
wired
wrong.
2.
Coil
L7,
L8,
or
L9.
3.
Coaxial
cable
between
Band
switch
and
relay
K1.
4.
Band
switch
SW2A,
B,
C,
D,
or
E.
5.
Variable
capacitor
C31.
1.
Interconnection
to
exciter.
2.
Setting
of
control
R2.
1,
Cables
to
input
filter
chassis
are
interchanged.
2.
Band
switch
SW2A,
B,
C,
D,
or
E.
3.
Coils
L1
through
LS.
Plata
current
does
not
increase
with
added
drive
power.
1.
Exciter
and
Amplifier
are
set
to
different
bands.
2.
Band
switch
SW2A,
B,C,
D,
or
E.
8.
Coils
L1
through
L6.