Heatilator • NDV30-IFT, NDV33-IFT, NDV36-IFT, NDV36-IFT-NVR, NDV42-IFT Installation Manual • 2620-980 Rev. C • 8/20
4
B. Glass Specications
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as dened by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certied to the
requirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certication Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01
and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 “Certication and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…
Such certicate shall accompany the product or shall oth-
erwise be furnished to any distributor or retailer to whom
the product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Specications
This product is listed to ANSI standards for “Vented Gas
Fireplace Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for
Use at High Altitudes”.
A. Appliance Certication
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
1 1
Product Specic and Important Safety Information
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
In CANADA: Input ratings are certied without a
reduction of input rate for elevations up to 4500 feet
(1370 m) above sea level. Please consult provincial
and/or local authorities having jurisdiction for
installations at elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
orice size.
MODELS: NDV30-IFT, NDV30L-IFT,
NDV33-IFT, NDV33L-IFT
NDV36-IFT, NDV36L-IFT
NDV36-IFT-NVR
NDV42-IFT, NDV42L-IFT
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: CSA / ANSI Z21.88:19 • CSA 2.33:19
Models
(U.S. or Canada)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Orice
Size (DMS)
NDV30-IFT (NG)
(0-2000 FT)
20,000 14,000
.083 in.
NDV30L-IFT
(Propane)
(0-2000 FT)
18,500 13,500
1.25 mm
NDV33-IFT (NG)
(0-2000 FT)
22,000 15,000
#43
NDV33L-IFT
(Propane)
(0-2000 FT)
20,000 14,500
#55
NDV36-IFT (NG)
(0-2000 FT)
25,000 17,000
#42
NDV36L-IFT
(Propane)
(0-2000 FT)
24,000 17,000
#54
NDV36-IFT-NVR
(NG)
(0-2000 FT)
25,000 17,000
#42
NDV36-IFT-NVR
(Propane)
(0-2000 FT)
24,000 17,000
#54
NDV42-IFT (NG)
(0-2000 FT)
27,500 19,500
#39
NDV42L-IFT
(Propane)
(0-2000 FT)
26,500 18,500
#53