MINIMUM CLEARANCE SEPARATION SPECIFICATIONS
The HEATMOR™ furnace, is certied to be installed outside, away from other buildings.
Please observe the following “Clearance to Combustibles” guidelines. If you have any fur-
ther questions, which are not addressed in this Operators Manual, please contact your local
dealer for further information.
• To HEATMOR™ Stainless Steel Outdoor Furnace BACK. 96"
• To HEATMOR™ Stainless Steel Outdoor Furnace TOP 18"
• To HEATMOR™ Stainless Steel Outdoor Furnace FRONT 48"
• To HEATMOR™ Stainless Steel Outdoor Furnace Chimney 18"
• To HEATMOR™ Stainless Steel Outdoor Furnace Sides 6"
• DO NOT store combustible liquids or materials near the furnace
• It is not recommended to install the furnace in any form of building
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in the United
States, always check any and all applicable state and local regulations and inform your
insurance agent.
Before installing your HEATMOR™ Stainless Steel Outdoor Furnace, if in Canada, always
check any and all applicable Provincial and Municipal regulations and inform your insur-
ance agent.
HEATMOR™ Inc. strongly recommends not installing a HEATMOR™ Stainless Steel Out-
door Furnace within 50 feet of any ammable structure.
A HEATMOR™ Stainless Steel Outdoor Furnace should be located with consideration to
your neighbor’s property and in accordance with local ordinances. Refer to the “Best Burn
Practices” for further operating considerations.
HEATMOR™ Outdoor Furnace, is not designed or certied to be located in densely popu-
lated areas.