INSTALLATION
Installation guidelines
The following information is for guidance only.
Locating the Unit
The unit should be located on a solid, flat, horizontal surface. Ensure 3 meters of free air flow to the
discharge panel and 1 meter to the inlet panel. Ensure adequate access to the controller and for
maintenance purposes.
Precautions
-Avoid locating the unit close to bedrooms or other noise sensitive areas.
-Avoid a location which could create vibration i.e. secured to a solid wall.
-Try to avoid placing the unit under a tree or exposed to extreme conditions.
Water connection
The heat pump is connected to a filtration circuit with a by-pass.
It is imperative that the by-pass is placed after the pump and the filter.
The by-pass generally consists of 3 valves.
This makes it possible to regulate the water flow which passes through the heat pump and to isolate the
heat pump completely for any maintenance work, without cutting the flow of filtered water.
If your installation is equipped with a water treatment system (chlorine, bromine, salt etc.) the by-pass must
be installed before the water treatment, with a non-return valve between the by-pass and water treatment
system.