4. Clean the cover of the machine, especially the ventilation holes.
5. If any of the parts of the machine is cleaned by water or a damp cloth, etc., it must be
completely dry. Then the metal parts must be grease against the corrosion with suitable
protective oil. Make sure that the water doesn´t leak into the internal parts of the machine.
6. Potential damage of the parts due to corrosion, can not be assessed as a manufacturing or
material defect.
STORAGE
Store the machine out of reach of children.
Turn the motor off and disconnect the mains plug if the machine is not used.
Allow let the machine to cool down before storage.
Do not store the machine a long time in direct sunlight.
Replace worn or damaged parts for safety.
Store machine in a clean, dry, dark and frost-free place, protected from dust and out of
reach of children. The ideal storage temperature is between 5 °C and 30 °C.
Use the original packaging to storage whenever possible.
Cover unit with a suitable protective cover that does not retain moisture. Do not use sheet
plastic as a dust cover. A nonporous cover will trap moisture around the machine, promoting
rust and corrosion.
The temperature for transport and storage can range from -25 °C to 55 °C.
The maximum temperature must not exceed 70 °C.
TRANSPORT
Turn the motor off and disconnect the mains plug. When transporting, be careful not to drop,
or otherwise shock the machine. For transport, the machine has to be fixed against slipping and
tipping over. Do not place objects on the machine.
TROUBLESHOOTING
CAUTION! A
You cannot rectify disorders that require more intervention yourself.
If you‘re unable to rectify the fault using the corrective measures described below,
contact a specialist garage, preferably an authorised service centre.
Improper handling can cause damage or serious injuries.
PROBLEM PROBABLE CAUSE CORRECTIVE ACTION
The operating
switch is closed, but
the motor does not
rotate
Power not connected. Connect the machine to the power supply.
The wires are bent or broken. Check the cables. Have them replaced if necessary.
Malfunction of switches, motor,
defective starting capacitor, etc.
Visit an authorized service centre.
Equipped with current or
the emergency stop button has
been pressed
Turn the emergency button in the direction of
the arrows.