6 Sensors
Digital Governor Basic System PANDAROS III 13
6 Sensors
6.1 Overview
Sensor
Speed
Oil Pressure
Boost Pressure
HZM Designation
IA ..
DSO 01-6
DSO 01-10
DSL/G 0..-2
DSL/G 0..-5
DSL/G 0..-10
Connection
SV 6-IA-2K
2 pole
DIN 43650 A
2 Line System
DIN 43650 A
2 Line System
Measuring Procedure
inductive, active
active
active
Measuring Range
50...9.000 Hz
0...6 bar
0...10 bar
0...2 bar
0...5 bar
0...10 bar
Supply Voltage
Range
10...34 V DC
12...36 V DC
Output Signal Range
0...10 V AC
4...20 mA
4...20 mA
Operating
Temperature Range
-55...+120°C
-25...+125°C
-40...+100°C
In order to ensure maximum flexibility with regard to the sensors, the minimum/ maximum
current values and the measuring ranges of the pressure and temperature sensors have been
provided programmable.