Water Pressure: A minimum of 25 pounds of water pressure
(psi) is required for regeneration. Maximum 125 psi.
Water Quality: On rural water supplies there is often a problem
with sand or sediment in the water. (This problem occasionally
occurs in public water supplies.) If the water is not ltered before
being softened, the sand and sediment will plug up the water
softener restricting the ow through the resin bed. This problem
often requires rebedding of the mineral tank. Note: Well and/or
pump problems aecting the operation of the softener are repairs
that are not covered under warranty. To prevent these unneces-
sary, and expensive repairs that are not covered under warranty,
we recommend the installation of an in-line lter system ahead
of softener installations.
Electrical: A continuous 110 volt 60 cycle current supply is
required. Make certain the current supply is uninterrupted and
cannot be turned o with another switch. All electrical connec-
tions must be connected per local codes. Surge protection is
recommended with all electric controls.
Existing Plumbing: Condition of existing plumbing must be
free from lime and iron build-up. Piping that is built-up heavily
with lime and/or iron must be replaced. If piping is blocked with
iron, additional equipment must be installed ahead of the water
conditioner to correct the problem.
Drain Line: The conditioner should be located close to a drain.
Avoid overhead drain lines if possible to prevent back pressure
on the brine injector. Overhead drains are not to exceed 8 feet
above the oor and no more than 20 feet in length. The pipe
size for the drain line should be a minimum of 3/4”. Backwash
ow rates in excess of 7 gpm or length in excess of 20’
require 1” drain line.
Bypass Valves: Always provide for the installation of a bypass
valve.
Softening: It is recommended that the conditioner be installed
to soften both the hot and cold water supply. A separate hard
water faucet may be plumbed for drinking purposes if you desire.
Outside faucets should be left on hard water.
Caution: Water temperature is not to exceed 110°F; the condi-
tioner cannot be subject to freezing conditions, or to a vacuum
due to loss of pressure (such as a water main break).
PRE-INSTALLATION CHECK LIST
Figure 5
Figure 4
(All electrical & plumbing should be done in accordance to all local codes)