EasyManua.ls Logo

Henco LOGIC - 11. Maintenance; Cleaning Instructions; 12. Technical Characteristics; Technical Specifications

Henco LOGIC
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
English
|
Nederlands
|
Français
|
Deutsch
12. TECHNICAL CHARACTERISTICS
This thermostat can be used in conditions described below:
11. MAINTENANCE
Cleaning of the thermostat
Gently dust the outside of the thermostat with
a soft, lint-free cloth.
If the thermostat needs a more thorough
cleaning:
- Lightly dampen a soft and clean cloth with
water.
- Wring out any excess water from the cloth.
- Gently wipe the display and sides of the
thermostat, making sure no drops of water
accumulate around the product.
Important: Do not spray thermostat directly
with water, or use cleaning solutions or polish-
es, as doing so may damage the thermostat.
IP20
C to 50°C (32°F to 122°F)
24AC to 230VAC
NTC 10kΩ at 25°C
24VAC: Max. 5 actuators (1,6W/actuator)
230VAC: Max. 8 actuators (1,8W/actuator)
Comfort / Reduced / Anti-freeze 5 to 35°C /
5 to 35°C / 0.5 to 10°C / (increments of 0.5°C)
Proportional band (cycles 15-30-45-60 min)
or hysteresis 0.C to 3.0°C
Class IV (2%)
-20°C to 60°C (-4°F to 140°F)
In option
IP
Ambient operating temperature
Power Supply
Temperature sensor Internal
and/or external (optional)
Power output Live Triac, NO or NC
Temperature ranges
Regulation type
ERP
Storing temperature
Internal humidity sensor

Table of Contents