Problems and solutions
User manual COMPACT-range 13
Problems Cause Solution
Insufficient vacuum in the
bag
The vacuum pouch is of
inferior quality.
The product has damaged the
pouch.
There is insufficient room
between the sealing bar and
the counter bar
Select vacuum pouches of a better
quality.
Use a new pouch.
Check the position of the sealing bar
The vacuum pouch is
incorrectly sealed.
The vacuum pouch is
incorrectly placed on the
sealing bar.
The sealing time is not set
correctly.
There is a break in the sealing
wire.
The sealing bars are dirty.
The Teflon tape is worn.
The counter bar is damaged.
The vacuum pouches are of
inferior quality.
The opening of the vacuum
pouch is contaminated.
Place the opening of the vacuum
pouch over the sealing bar correctly.
Adjust the sealing time value.
Replace the sealing wire.
Clean the sealing bars.
Replace the Teflon strip
Replace the silicon strip.
Select better quality vacuum pouches.
Remove any obstructions from the
opening of the pouch. Make sure the
opening of the package remains clean
while filling. or replace the bag