Problems and solutions
User manual COMPACT-range 13
Problems Cause Solution
Insufficient vacuum in the
bag
• The vacuum pouch is of
inferior quality.
• The product has damaged the
pouch.
• There is insufficient room
between the sealing bar and
the counter bar
• Select vacuum pouches of a better
quality.
• Use a new pouch.
• Check the position of the sealing bar
The vacuum pouch is
incorrectly sealed.
• The vacuum pouch is
incorrectly placed on the
sealing bar.
• The sealing time is not set
correctly.
• There is a break in the sealing
wire.
• The sealing bars are dirty.
• The Teflon tape is worn.
• The counter bar is damaged.
• The vacuum pouches are of
inferior quality.
• The opening of the vacuum
pouch is contaminated.
• Place the opening of the vacuum
pouch over the sealing bar correctly.
• Adjust the sealing time value.
• Replace the sealing wire.
• Clean the sealing bars.
• Replace the Teflon strip
• Replace the silicon strip.
• Select better quality vacuum pouches.
• Remove any obstructions from the
opening of the pouch. Make sure the
opening of the package remains clean
while filling. or replace the bag