Looking after your machine
8 User manual COMPACT-range
3 LOOKING AFTER YOUR MACHINE
Regular and thorough maintenance prevents breakdowns, prolongs the machine’s operational life and
guarantees optimum hygiene.
3.1 Warnings
Always unplug the machine when carrying out maintenance or repairs.
To prevent accidents always replace damaged or oxidized gas or torsion springs in the lid.
Never use high-pressure water to clean the machine as this can cause irreparable damage to the
machine and to the electronics.
An authorized service representative must carry out repairs.
3.2 Clean Daily
Clean the lid, insert plates, bottom and walls of the vacuum chamber with a damp clothe.
Pay particular attention to the silicon strip in the lid.
Do not clean the transparent lid with synthetic cleaning agent as this weakens the acrylic material.
Clean the control panel with a dry cloth.
In order to prevent oxidation in the pump, the vacuum pump must run for about 5 minutes after
cleaning, (see “Warm up” procedure) to allow the condensed water in the oil can evaporate.
3.3 Weekly maintenance (See Section below “Seal bar Check list”)
Check the oil, add oil if necessary. (Section below correct oil specifications)
Check the condition.
Check the silicone gasket in the lid; replace if damaged.
Check the silicone strip in the counter bar; replace if damaged.
3.4 Monthly maintenance
Check the condition of the oil. (See “Oil” section below for correct specification)
Note: Replace the oil after 160 hours of operation.
If the machine is not used frequently, change the oil every 6 months.
3.5 Annual maintenance
Check the condition of the vacuum hoses and pipes and replace them if necessary.
Check the condition of the silicone strip of the counter bar and replace if necessary.
Check the condition of the gas springs in the lid and replace them if necessary.
3.6 Oil
The oil in the vacuum pump must be checked and replaced on a regular basis.