Example:
Using COMMAND 1 to activate a boiler with a verification of the executed command on
INPUT 1.
P
rogramming:
• Associate INPUT 1 to COMMAND 1
• Record the ACTIVATION COMMAND MESSAGE “Boiler activated”, and record the
DEACTIVATION COMMAND MESSAGE “Boiler deactivated”.
• Programme OUTPUT 1 as IMPULSIVE for 5 seconds.
Connections:
Connect the dialler output 1 to the boiler activation command and the dialler input 1 on
the output which switches the boiler on.
Command execution
Remotely connect to INFORM 600 phone dialler, see REMOTE ACCESS; activate input
1 and wait until the dialler announces “Boiler activated”. This way the dialler confirms
that the command has been successfully executed.
LINE OPTIONS
With this heading, it is possible to programme the PSTN phone line options. When
“LINE OPTIONS FUNCTION SELECTION” is displayed, press [
OK
] and use [
▲
] and
[
▼
] to run through all the line options; press [
OK
] to select the required option and
use [
▲
] and [
▼
] to choose the programming of the required option; press [
OK
] to
confirm or [
CLR
] to exit.
LINE OPTIONS SUB-MENU
FAILURE SIGNALLING DELAY
40
(1
:
240
sec)
SELECTION
DTMF
DECADICA
TONE DETECTION
TOT
AL
P
ARTIAL
DISABLED
ANSWERING RINGS
0
(0
:
15 rings
)
ANSWER MACHINE
EXCLUSION
NO
SI
✔
Default options are in bold
.