Safety requirements for electrical equipment for measurement, control, and laboratory use.
EMC requirements for electrical equipment for measurement, control, and laboratory use.
Directives applied for conformity assessment procedures, including IVD directive.
Medical device regulations applicable in the USA and Canada.
Systems certified according to ISO 9001, ISO 13485, and ISO 14001.
Explains the intended use of the medical product (laboratory centrifuge) and defines non-intended uses.
Details potential risks associated with improper use or handling of the centrifuge.
Provides detailed technical data including manufacturer, model, voltage, capacity, and dimensions.
Essential precautions for operating the centrifuge safely and preventing damage.
Guidelines for initial setup, moving, and general operational safety.
Rules for rotor installation, loading, speed limits, and handling hazardous materials.
Procedures for centrifuging hazardous materials and using biosafety systems.
Explains symbols on the device and in the document for hazard and information.
Lists all items included with the centrifuge for verification.
Procedures for positioning, connecting, and powering on the centrifuge.
Instructions for opening and closing the centrifuge lid safely.
Step-by-step guide for mounting and dismounting the rotor.
How to symmetrically load samples into the rotor, respecting weight limits.
How to properly close biosafety systems for secure containment.
Details the symbols, indicators, and keys on the centrifuge's control panel.
Explains how to set speed, running time, and other operational parameters.
Guides the user through setting the desired rotor run-down time (brake step).
How to set a specific time for the centrifugation run.
How to run the centrifuge continuously without a set time limit.
How to perform short bursts of centrifugation by holding a button.
Explains Relative Centrifugal Force and its calculation for sample separation.
How to adjust speed when centrifuging materials denser than 1.2 kg/dm³.
Step-by-step guide for manually opening the lid during power loss.
Instructions for cleaning, disinfecting, and removing contaminants from the main unit.
Procedures for cleaning, disinfecting, and handling rotors and accessories.
Information on which accessories can be autoclaved and precautions.
Instructions for handling centrifuge containers, especially after breakage.
Lists common faults, display codes, causes, and steps for resolution.
Step-by-step guide for safely changing the mains input fuses.
Information on returning the device and its environmentally sound disposal.
Detailed specifications and compatibility information for rotors and accessories.