User manual for poly-phase meter
18
9 Billing
9.1 Daily freezing
➢ At least store 62 days data
➢ Freezing time: 00:00 at everyday midnight
➢ Freezing content: Can configurable, same as load profile list(item 8.2)
➢ Daily freezing profile is the load profile which set period into 1440min.
9.2 Monthly billing
➢ Capacity: At least store 13 times data
➢ Automatic billing: When meter pass the preset billing time, the meter will billing
automatically. The format is XX date XX hour, default is 00 clock on each month
of 1st.
➢ Manual billing: Support send command or press-button billing. When meter in
scroll button display mode, long press the seal button for 10 seconds, and then can
see “-PrESS-bL” on display, now can press the down button and the LCD will
display “donE”, now means press-button billing finished. This function support
configure into enable or disable. Meter also support set two manual billing interval
into 0~65535s, default is 120s to reduce illegal repeat in short duration.
➢ Support supplement latest one billing data when meter power off or clock adjust.
➢ At most configure 60 objects one time, the list as follows:
◼ Clock
◼ Meter serial number
◼ Import active energy
◼ Export active energy
◼ Import active energy in L1
◼ Export active energy in L1
◼ Import active energy in L2
◼ Export active energy in L2
◼ Import active energy in L3
◼ Export active energy in L3
◼ Combined active energy
◼ Reactive energy in QI
◼ Reactive energy in QII
◼ Reactive energy in QIII
◼ Reactive energy in QIV
◼ Reactive energy in QI in L1