EasyManua.ls Logo

HEXING HXF300 - Billing; Daily Freezing; Monthly Billing

Default Icon
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual for poly-phase meter
18
9 Billing
9.1 Daily freezing
At least store 62 days data
Freezing time: 00:00 at everyday midnight
Freezing content: Can configurable, same as load profile list(item 8.2)
Daily freezing profile is the load profile which set period into 1440min.
9.2 Monthly billing
Capacity: At least store 13 times data
Automatic billing: When meter pass the preset billing time, the meter will billing
automatically. The format is XX date XX hour, default is 00 clock on each month
of 1st.
Manual billing: Support send command or press-button billing. When meter in
scroll button display mode, long press the seal button for 10 seconds, and then can
see -PrESS-bL on display, now can press the down button and the LCD will
display donE, now means press-button billing finished. This function support
configure into enable or disable. Meter also support set two manual billing interval
into 0~65535s, default is 120s to reduce illegal repeat in short duration.
Support supplement latest one billing data when meter power off or clock adjust.
At most configure 60 objects one time, the list as follows:
Clock
Meter serial number
Import active energy
Export active energy
Import active energy in L1
Export active energy in L1
Import active energy in L2
Export active energy in L2
Import active energy in L3
Export active energy in L3
Combined active energy
Reactive energy in QI
Reactive energy in QII
Reactive energy in QIII
Reactive energy in QIV
Reactive energy in QI in L1

Related product manuals