Harrington Generators International
498-1084 36 HRD060D Diesel Generator
Datasheets and Specications
CN222
Instructions
498-1028 Iss A
Harrington Generators International Limited VAT No 184 4733 43 Registered (England) Reg No 2184794
Registered Of ce: Precision House, Arden Road, Alcester, Warwickshire, B49 6HN
To reset the timer, the module top plate will need to
be removed by unfastening the screws (Item B, Fig
2). The timer relay (Item A, Fig 4) is secured to the
base of the enclosure by a self adhesive pad. To
access the timer controls the timer will need to be
gently detached.
There are two timer control selectors ( g 5) on the
front face of the relay. Item A is the rough time range
selector, Item B is the ne timer adjustment. The third
selector is the function adjustment - DO NOT adjust
this dial.
To re-set the timer use a small screwdriver to rstly
set the rough time range into a time bracket as in
Fig 6.
To change the time range move the position of the
pointed slot to the new time range required. The
movement will click through the increments until the
selected range is reached.
After this set the ne time delay adjustment (Item B,
Fig 5 and Fig 7). This is based upon a decimal frac-
tion scale of the rough time range selected, i.e. each
increment is a tenth of the maximum value of the
rough time range.
For example,
To set the timer to operate for 30 minutes, set the
rough time range to the 0.1- 1 hr selection and then
set the ne adjustment dial to position .5
To set the timer to operate for 3 hours, set the rough
time range to the 1-10 hr bracket and then set the
ne adjustment dial to position .3
Again the selector will click into the incremental set-
ting.
When reset replace the timer relay back into the
module replacing self adhesive pad if necessary.
Replace the top plate and secure with the screws
extracted earlier and re-site on cabin wall.
Check the new timer setting by starting the generator
and observing the timed stopping of the generator
after the elapsed timer period.