Harrington Generators International
3
498-1084 HRD060D Diesel Generator
Specication
Specication
General Specication
Output Power & Power Factor:
6.0 kVA 4.8kW CTE Single Phase stand by power
5.4 kVA 4.3kW CTE Single Phase prime power
Power Factor 0.8
Environment:
Temperature range: -10°C (without additional starting aids) to +40°C
Relative Humidity: 10% to 90%
Altitude sea level to +1000m (with slight derate)
Performance Class ISO 8528:
Electrical Class G1
Steady state voltage: +/- 10% Frequency droop < 8%
LTP: Limited Time Performance
Overload Capability: n/a
Fuel: Commercial diesel with up to 10% bio-diesel i.e. B10 blend.
Voltages and Frequency: 230V/110V 50 Hz
Output Current: 400V - 230V 26.1A 110V 52.2A
Output Type: Switched
Sockets 110V 2 x 16A, 1 x 32A
Sockets 230V 1 x 16A, 1 x 32A
Sockets Position: Control Panel
Electrical Protection Devices: 2-pole main 25A MCB and individual socket breakers
Other: Buccaneer Socket for remote panel/AMF start/stop connection
Generator Control System: Deep Sea Electronics Engine and Generator Control Module
Starting Method: Electric Start via Control Module as local or remote start.
Control Module: DSE3110
Engine Protection: Low Oil Pressure, Low Fuel
Engine Monitoring: Battery voltage, hours run.
Electrical Protection: Over/Under Speed, Voltage, Frequency
Electrical Monitoring: Volts, Frequency
Engine model: Yanmar L100N
Service Interval: 200 hours (rst oil change at 50 hours)
Cylinders: 1
Power: 6.5 kW
Engine Speed: 3000 rpm
Engine Cooling: Air cooled
Starting Method: Electric Start
Electrical System: 12V DC system
Emissions Level: n/a below threshold.
Lowest starting temperature: -10°C without extra aids
Other: n/a