3.7 Correct Defective Pixel
The device can correct the defective pixels on the screen which are not performed as expected.
Steps
1. Hold to show the menu.
2. Select .
3. Press , , , and to move the cursor to the position of dead pixel.
4. Press to correct the dead pixel.
Note
The selected defective pixel can be magnified and displayed at the bottom right of the interface.
Figure 3-3 Correct Defective Pixel
3.8 Flat Field Correction
The image calibration function can correct non-uniformity of display.
Steps
1. Hold to go to the menu.
2. Select and press to switch FFC mode.
– Manual: Hold in live view to trigger image calibration.
– Auto: The device performs FFC automatically according to the set schedule when switching
on the camera.
– External: Cover the lens cover, then hold in live view to trigger calibration.
3. Hold to save the settings and exit.
3.9 Set Picture in Picture Mode
Steps
1. In the view mode, hold to show the menu.