12
1. Set the DIP switch of No. 6 as 0.
2. Set the DIP switch of No. 1 ~ 5 for RS-485 address and
reading card mode. For details, please refer to 3.2
Introduction for DIP Switch.
3. Wire the cable between controller and card reader as
shown below.
Figure 3-4 Wiring for RS-485 Communication Mode
Steps for Wiegand communication mode:
1. Set the DIP switch of No. 6 as 1.
2. Set the DIP switch of No. 5 and 7 for reading card mode and
Wiegand protocol. For details, please refer to 3.2
Introduction for DIP Switch.

Other manuals for HIKVISION DS-K1104MK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-K1104MK and is the answer not in the manual?

HIKVISION DS-K1104MK Specifications

General IconGeneral
Quantity per pack1 pc(s)
InternalNo
Product colorBlack, Silver
Built-in processorYes
Compatible memory cards-
RS-485 ports1
TypeBasic access control reader
CertificationFCC, CE
LED indicatorsStatus
RFID frequency13.56 MHz
Authentication typeAccess chip/card, Password
Supported protocolsMifare
Keypad number of keys12
RFID reading distance50 mm
International Protection (IP) codeIP65
Operating temperature (T-T)-20 - 65 °C
Operating relative humidity (H-H)10 - 90 %
Power consumption0.5 mA