The device can read the data from FeliCa card when enabling the FeliCa card funcon.
Set Card No. Authencaon Parameters
Set the card reading content when authencate via card on the device.
Go to
Conguraon → Card Sengs → Card No. Authencaon Sengs .
Select a card authencaon mode and click Save.
Full Card No.
All card No. will be read.
Wiegand 26 (3 bytes)
The device will read card via Wiegand 26 protocol (read 3 bytes).
Wiegand 34 (4 bytes)
The device will read card via Wiegand 34 protocol (read 4 bytes).
9.5.15 Set Privacy Parameters
Set the event storage type, picture upload and storage parameters, and the picture clearing
parameters.
Go to
Conguraon → Security → Privacy Sengs
Event Storage
Sengs
Select a method to delete the event. You can select from Delete Old Events Periodically, Delete
Old Events by
Specied Time, or Overwring.
Delete Old Events Periodically
Drag the block or enter number to set the period for event deleng. All events will be deleted
according to the
congured me duraon.
Delete Old Events by Specied Time
Set a me and all events will be deleted on the congured me.
Overwring
The earliest 5% events will be deleted when the system detects the stored events has been over
95% of the full space.
Authencaon
Sengs
Display Authencaon Result
You can check Face Picture, Name, and Employee ID, to display the authencaon result.
Name De-idencaon
You can check Name De-idencaon, and the whole name will not be displayed.