EasyManua.ls Logo

HIKVISION DS-K3BC430LX Series - Wiring; Alarm Input Wiring

HIKVISION DS-K3BC430LX Series
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note
There are 2 RS-485 interfaces on the access control board for entrance. Refer to Access Control
Board Terminal Descripon (Oponal) for details.
There are 2 RS-485 interfaces on the oponal board for exit. Refer to for details.
If there are other RS-485 devices
connecng, the ID of the RS-485 cannot be conicted.
The connected 12 V power interface for the face
recognion terminal cannot be connected with
other 12 V devices.
Figure 4-8 Wiring RS-485
4.3.7 RS-232 Wiring
Note
There is 1 RS-232 interface on the extended interface of access control board, see Access Control
Board Terminal Descripon (Oponal) . The RS-232A corresponds to UART 1 on web.
There is 1 RS-232 interface on the oponal board, see . The RS-232B corresponds to UART 2 on
web.
The RS-232C interface is reserved.
Figure 4-9 RS-232 Wiring
4.3.8 Alarm Input Wiring
On the main lane control board, you can wire the re alarm input interface.
DS-K3BC430LX Series Swing Gate
17

Table of Contents