Set Wiegand Parameters
You can set the access control device's Wiegand channel and the communicaon mode. Aer
seng
the Wiegand parameters, the device can connect to Wiegand card reader via Wiegand
communicaon.
Before You Start
Add access control device to the client, and make sure the device supports Wiegand.
Steps
1.
Enter the Access Control module.
2.
On the
navigaon bar on the le, enter Advanced Funcon → More Parameters .
3.
Select an access control device in the device list and click Wiegand to enter the Wiegand
Sengs page.
4.
Set the switch to on to enable the Wiegand
funcon for the device.
5.
Select the Wiegand channel No. and the communicaon mode from the drop-down list.
Note
If you set Communicaon Direcon as Sending, you are required to set the Wiegand Mode as
Wiegand 26 or Wiegand 34.
6.
Click Save.
The congured parameters will be applied to the device automacally.
Aer changing the communicaon direcon, the device will reboot automacally.
Enable M1 Card
Encrypon
M1 card encrypon can improve the security level of authencaon.
Steps
Note
The funcon should be supported by the access control device and the card reader.
1.
Enter the Access Control module.
2.
On the
navigaon bar on the le, enter Advanced Funcon → More Parameters .
3.
Select an access control device in the device list and click M1 Card Encrypon to enter the M1
Card Encrypon page.
4.
Set the switch to on to enable the M1 card
encrypon funcon.
5.
Set the sector ID.
The sector ID ranges from 1 to 100.
6.
Click Save to save the
sengs.