7
Specificaon
6
Operaon Cauon and Device Maintenance
- All the electronic operaon should be strictly compliance with the electrical safety regulaons, fire prevenon
regulaons and other related regulaons in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon.
Avoid the equipment installaon on vibraons surface or places subject to shock (ignorance can cause equipment
damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then
please contact the service center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon.
Avoid the equipment installaon on vibraons surface or places subject to shock (ignorance can cause equipment
damage).
- Do not place the device in extremely hot (refer to the specificaon of the device for the detailed operaon
temperature), cold, dusty or damp locaons, and do not expose it to high electromagnec radiaon.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or radiator is forbidden
(ignorance can cause fire danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not
a malfuncon however), and affecng the endurance of sensor at the same me.
- Improper use or replacement of the baery may result in hazard of explosion. Replace with the same or
equivalent type only. Dispose of used baeries according to the instrucons provided by the baery manufactur-
er.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situaon.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
6
Note: when the low voltage message appears there will be at least 30 days of use.
Detecon Method Passive Infrared
Sensor Model SBG4L46-711
Detecon Range
Detecon Angle
Detecon Zones
Detectable Speed
Sensivity
White Light Filter
Digital Temperature Compensaon
Digital Processing Support
Sealed Opcs Support
Tamper Protecon Front,Rear
Environment Temperature Indicator Support
Signal Strength Indicator Support
Power Switch Power Up Enrolling
LED Indicator Blue(Alarm)
Transmission Technology Tri-X Wireless
Transmission Method Two-Way RF Wireless
Transmission Frequency 868 MHz/433 MHz
Transmission Security AES-128 Encrypon
Transmission Range (Open area) 1600 m (868 MHz)/800 m (
433 MHz)
Frequency Hopping Support
Enrolling Method Power up,Remote ID,QR Code
Power Supply Baery Powered
Baery Type CR123A × 1
Typical Voltage 3V
Standard Baery Life 5 years in work status (being triggered 20 mes per day)
Operaon Temperature -10 °C to 55 °C (14 °F to 131 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F)
Operaon Humidity 10% to 90%
Dimension (D × D) 101.2 mm x 32.9 mm
Weight 109.5 g
Mounng Height 2.4 to 4m
Mounng Method Ceiling
Applicaon Scenario Indoor