EasyManua.ls Logo

HIKVISION DS-PHA48-EP

HIKVISION DS-PHA48-EP
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
115
C. Output Types
Table C-1 Output Types
Output Types
Active
Restore
Arming
Arm the AX HYBRID PRO
After the configured output
delay
Disarming
Disarm the AX HYRBID PRO
After the configured output
delay
Alarm
When alarm event occurs. The
alarm output will be activated
after the configured exit/enter
delay.
After the configured output
delay, disarm the AX HYBRID
PRO or silence alarm
Zone Linkage
When alarm event occurs, the
linked relay will output alarm
signal.
After the configured output
duration
Manual Operation
Enable relays manually
Over the triggering time or
disable the relays manually