EasyManuals Logo

HIKVISION HWI-B120H-U User Manual

HIKVISION HWI-B120H-U
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
Network Camera User Manual
132
change should be to trigger the detection.
Sound Intensity Threshold: Range [1-100], it can filter the sound in the
environment, the louder the environment sound, the higher the value should
be. You can adjust it according to the real environment.
You can view the real-time volume of the sound on the interface.
5. Click Arming Schedule to set the arming schedule. Refer to Task 2 Set the
Arming Schedule for Motion Detection in Section 10.1.1 for detailed steps.
6. Click Linkage Method and select the linkage methods for audio exception,
including Notify Surveillance Center, Send Email, Upload to FTP/Memory
Card/NAS, Trigger Channel for recording and Trigger Alarm Output.
7. Click Save to save the settings.
Configuring Defocus Detection
Purpose:
The image blur caused by defocus of the lens can be detected, and some certain
actions can be taken when the alarm is triggered.
Note: Defocus detection function varies according to different camera models.
Steps:
1. Enter the Defocus Detection settings interface, Configuration > Event > Smart
Event > Defocus Detection.
Configuring Defocus Detection
2. Check the checkbox of Enable to enable the function.
3. Click-and-drag the slider to set the detection sensitivity. The sensitivity value
ranges from 1 to 100, and the higher the value is, the more easily the defocus

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION HWI-B120H-U and is the answer not in the manual?